OA 5644 serija
OA 5644 serija
• According to DIN EN 61810-1, DIN EN 61810-3, DIN EN 45545 (fire protection on railway vehicles)
• With forcibly guided contacts
• Safe separation betwenn coil/contact and contact/contact for applications at pollution degree 2 with rated insulation voltage 250 V
• Clearance and creepage distances
contact – coil ≥ 5.5 mm
contact – contact ≥ 5.5 mm
• Low nominal and holding power
• High mechanical service life
• Extremly smallest height only 10.3 mm and minimum area
• RoHS compliance
• Placing SMD components between PCB and relay is possible